Description

A block of gas fittings to control the supply of gas from the source tanks (at 16 bar) to the various segments of the system (small puffer segments and large puffers)

Requirements

  • Regulate 16 bar supply to pressures needed for each connected segment (0-2 bar for small puffers 0-4 bar for large puffers)
  • Have a single 1/4 turn cut off valve for the whole system (this is from the Burning Man Fire Effect guidelines)
  • Have isolation valves for each segment so that each can be connected and tested individually
  • Have pressure gauges for each pressure delivered

Design

A primary regulator is used to drop tank pressure (16 bar) to the highest pressure required by a working segment (large puffers). A secondary regulator is placed on a spur which is then split to link the three small puffer segments at a lower pressure.

Fire Pong Supply and Regulation Segment Diagram.png.

See also: Master Parts List

Contributers