Resin Calibration Charts: Difference between revisions

From Nottinghack Wiki
Jump to navigation Jump to search
Moop (talk | contribs)
No edit summary
Moop (talk | contribs)
mNo edit summary
Line 23: Line 23:
The numbers at the bottom of the card are the exposure time for that column in multiples of 2 seconds. The features in the column start at 1mm and decrease by 0.1mm with each row. After 0.1mm the features decrease by 0.01mm per row. The resolution of the printer is 0.045mm so the lower four rows are not expected to be correct.
The numbers at the bottom of the card are the exposure time for that column in multiples of 2 seconds. The features in the column start at 1mm and decrease by 0.1mm with each row. After 0.1mm the features decrease by 0.01mm per row. The resolution of the printer is 0.045mm so the lower four rows are not expected to be correct.


Start from top and locate first well formed circle column
- Start from top and locate first well formed column
Move to bottom last visible Circle
- Move to bottom last visible circle
Move right untill the circle starts to clog
- Move right until the circle starts to clog
Backtrack one colum
- Backtrack one column
That's your sweetspot
- That's your sweetspot

Revision as of 17:25, 28 November 2019

A page to collate resin calibration charts for the Anycubic Photon 3D printer.

It is possible to print a Calibration Chart for a specific layer height with your resin to find a good starting point.

This process requires changing the printer's settings, printing one or more charts, and then restoring the previous settings. **Please make sure you are confident that you can restore the standard settings before starting this process.**

AnyCubic Translucent Green with 20 micron layers
AnyCubic Translucent Green with 50 micron layers
AnyCubic Orange with 20 micron layers
AnyCubic Orange with 50 micron layers

As an opaque resin the AnyCubic Orange appears to require a much longer cure time (20s at 20 microns) and is very sensitive to bed levelling.

Test cards for AnyCubic Translucent Yellow resin will be uploaded when I am back in the space to photograph them.

Currently the test cards are being kept near the printer for ease of reference.

Reading the Test Cards

The numbers at the bottom of the card are the exposure time for that column in multiples of 2 seconds. The features in the column start at 1mm and decrease by 0.1mm with each row. After 0.1mm the features decrease by 0.01mm per row. The resolution of the printer is 0.045mm so the lower four rows are not expected to be correct.

- Start from top and locate first well formed column - Move to bottom last visible circle - Move right until the circle starts to clog - Backtrack one column - That's your sweetspot