Line 31: | Line 31: | ||
Found this crappy translation but it helps. | Found this crappy translation but it helps. | ||
http://www.imendit.com/item/57-86- | http://www.imendit.com/item/57-86-stepper-motor-driver-high-subdivision-4-3a-voltage-60vdc-12853688035.html | ||
Drive has 3 opto signal inputs, it can be either step/dir or CW/CCW control, Free is the enable signal. | Drive has 3 opto signal inputs, it can be either step/dir or CW/CCW control, Free is the enable signal. |
Revision as of 19:37, 13 June 2023
notes for later mesa wiring
https://www.mycncuk.com/threads/7658-BoBbing-up-and-down-like-this
The pins on the driver are :- 1 Step - 2 Step + 3 Dir - 4 Dir+ 5 Free - _enable ? 6 Free + 7 N.C. 8 N.C. 9 N.C. 10 N.C. 11 N.C. 12 N.C. 13 C pole Timing 14 E pole " 15 C pole OH (overheat ?) 16 E pole " . I am going to connect step+ and dir+ to +5v and use the step- and dir- to control the stepper. All the other pins will be unconnected. I am presuming that internal resistors in the driver will take care of the 'Free'. I have no idea what C pole and E pole means. .
https://www.cnczone.com/forums/stepper-motors-drives/176704-help-pin.html
Found this crappy translation but it helps. http://www.imendit.com/item/57-86-stepper-motor-driver-high-subdivision-4-3a-voltage-60vdc-12853688035.html Drive has 3 opto signal inputs, it can be either step/dir or CW/CCW control, Free is the enable signal. There are also 2 outputs for drive faults. Pulled and edited the relevant text: CW- CW+ Pulse signal input: Drive response to the rising edge of the pulse signal (internal optocoupler current to flow through) signal is high, the range of 4-5V, low 0-0.5V. For reliable response to the pulse signal, the pulse width should be greater than 2.5ms. DR/CC- DR / CC+ Direction of the signal / reverse pulse input: Single pulse signal for the direction, in order to ensure motor reliable commutation, the direction of the signal should be the pulse signal is at least 5ms establish. FREE- FREE+ (6 feet) Off-line signal input: When this signal is active, the drive to force cut off the motor current, the motor is in a free active when this signal is in an invalid state, the normal current of the driver output, the motor is locked. TIM Pole E-pole Motor relative to the origin of the signal output: This signal output and TIM light synchronization, in some specific occasions for. O. H Pole E-pole Protection action signal output: This output signal is synchronized with the O.H indicator. Use this signal when the drive protected action can notify the host computer drive is faulty.