Air Quality Monitoring: Difference between revisions
No edit summary |
|||
| (6 intermediate revisions by the same user not shown) | |||
| Line 10: | Line 10: | ||
__NOTOC__ | __NOTOC__ | ||
The air quality monitoring was funded via the [[Air Quality Monitoring Pledge Drive]]. All monitors report CO<sub>2</sub> and VOC index. In a few places the monitors also have PMSA003 sensors for PM1.0, PM2.5, PM10.0. These measurements are | The air quality monitoring was funded via the [[Air Quality Monitoring Pledge Drive]]. All monitors report CO<sub>2</sub> and VOC index. In a few places the monitors also have PMSA003 sensors for PM1.0, PM2.5, PM10.0. These measurements are published to [[MQTT Topics|MQTT]] on the topic <code>nh/air</code>, where they are then ingested into Prometheus for visualisation via Grafana (using a Node-RED flow). | ||
== Current Status == | == Current Status == | ||
The boards are gradually being built. Steve | The boards are gradually being built. Steve designed an enclosure for them. | ||
{| class="wikitable" | {| class="wikitable" | ||
| Line 21: | Line 21: | ||
! Location !! Measurements !! Status | ! Location !! Measurements !! Status | ||
|- | |- | ||
| Comfy Area || VOC, CO2 || | | Comfy Area || VOC, CO2 || {{Done}} | ||
|- | |- | ||
| Studio || VOC, CO2 || {{Done}} | | Studio || VOC, CO2 || {{Done}} | ||
|- | |- | ||
| Craft Room || VOC, CO2 || | | Craft Room || VOC, CO2 || {{Done}} | ||
|- | |- | ||
| Workshop || VOC, CO2, Particle || | | Workshop || VOC, CO2, Particle || {{Done}} | ||
|- | |- | ||
| Dusty || VOC, CO2, Particle || {{Done}} | | Dusty || VOC, CO2, Particle || {{Done}} | ||
| Line 33: | Line 33: | ||
| Metalworking || VOC, CO2 || | | Metalworking || VOC, CO2 || | ||
|- | |- | ||
| Electronics / 3D Printing || VOC, CO2, Particle || | | Electronics / 3D Printing || VOC, CO2, Particle || {{Done}} | ||
|- | |- | ||
| Blue Room || VOC, CO2 || | | Blue Room || VOC, CO2 || {{Done}} | ||
|- | |- | ||
| Art Room || VOC, CO2 || | | Art Room || VOC, CO2 || | ||
|} | |} | ||
| Line 44: | Line 44: | ||
The board is based around an Atmega 328p and WizNet W5500 Ethernet controller. There's a small buck supply to make powering the board more flexible. The VOC sensor used is a SGP40, and CO2 is reported with a SCD41. For boards which also measure air particles, they have a PMSA003 onboard. Out of curiosity and to help debugging, each board also has a INA219A chip and 0.1 ohm shunt. This allows the board to monitor its own power consumption. | The board is based around an Atmega 328p and WizNet W5500 Ethernet controller. There's a small buck supply to make powering the board more flexible. The VOC sensor used is a SGP40, and CO2 is reported with a SCD41. For boards which also measure air particles, they have a PMSA003 onboard. Out of curiosity and to help debugging, each board also has a INA219A chip and 0.1 ohm shunt. This allows the board to monitor its own power consumption. | ||
The PMSA003 can be added or removed if desired. The firmware will only publish PM values if the sensor is detected. We may want to add this to certain areas (e.g. [[Metalworking Downstairs]]) at some point. | |||
[[Category:Infrastructure]] | [[Category:Infrastructure]] | ||
Latest revision as of 19:25, 14 February 2026
| Air Quality Monitoring | |
|---|---|
| Primary Contact | Asj |
| Created | 01/01/2026 |
| Status | Active |
| Type | Hackspace Infrastructure |
The air quality monitoring was funded via the Air Quality Monitoring Pledge Drive. All monitors report CO2 and VOC index. In a few places the monitors also have PMSA003 sensors for PM1.0, PM2.5, PM10.0. These measurements are published to MQTT on the topic nh/air, where they are then ingested into Prometheus for visualisation via Grafana (using a Node-RED flow).
Current Status
The boards are gradually being built. Steve designed an enclosure for them.
| Location | Measurements | Status |
|---|---|---|
| Comfy Area | VOC, CO2 | |
| Studio | VOC, CO2 | |
| Craft Room | VOC, CO2 | |
| Workshop | VOC, CO2, Particle | |
| Dusty | VOC, CO2, Particle | |
| Metalworking | VOC, CO2 | |
| Electronics / 3D Printing | VOC, CO2, Particle | |
| Blue Room | VOC, CO2 | |
| Art Room | VOC, CO2 |
Hardware Description
The board is based around an Atmega 328p and WizNet W5500 Ethernet controller. There's a small buck supply to make powering the board more flexible. The VOC sensor used is a SGP40, and CO2 is reported with a SCD41. For boards which also measure air particles, they have a PMSA003 onboard. Out of curiosity and to help debugging, each board also has a INA219A chip and 0.1 ohm shunt. This allows the board to monitor its own power consumption.
The PMSA003 can be added or removed if desired. The firmware will only publish PM values if the sensor is detected. We may want to add this to certain areas (e.g. Metalworking Downstairs) at some point.